Sign In | Join Free | My burrillandco.com
Home > Plasma Surgery System >

MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator

Chengdu Mechan Electronic Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator from wholesalers
     
    Buy cheap MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator from wholesalers
    • Buy cheap MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator from wholesalers
    • Buy cheap MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator from wholesalers
    • Buy cheap MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator from wholesalers

    MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator

    Ask Lasest Price
    Brand Name : MECHAN
    Model Number : PLA-700
    Certification : CE, ISO13485
    Price : Negotiation
    Payment Terms : T/T, L/C
    Supply Ability : 100000 sets per year
    • Product Details
    • Company Profile

    MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator

    MIS Snoring Treatment System ENT Plasma Surgery System Low Temperature Coblator


    Product Introduction

    This PLA-700 ENT plasma surgery system are designed especially for ENT diseases treatment. it includes both ablation and coagulation modes, which result in different tissue effects. It is widely applying to Turbinate, Soft Palate, Uvula, CAUP, UPPP, Tonsillectomy, Adenoidectomy, Laryngeal tumor, Papilloma, Vocal Polyps etc.

    Product Diagram

    1 Plasma Generator2 Power Cord3 Footswitch Plate4 ABLATION Control
    5 PLACOAG Control6 Plasma Probe7 Receptacle of Footswitch8 Receptacle of Handle


    Working Principle

    A 50 μm plasma area is formed around the electrode through a conductive medium (mainly H2O, NaCl and air). Unlike traditional electrosurgical methods, which separate and solidify tissues by heating the tissue, Metron plasma knives use the kinetic energy generated by the rapid movement of plasma in an electric field at 100 kHz to decompose the tissue, thereby achieving the purpose of cutting and clotting.


    Technical Parameter

    Input Volts198-240V 50Hz
    100-120V 60Hz
    Export device could convert automatically per customer requirements
    Output PowerAblation or resection: ≤351W
    Coagulation or hemostasis: ≤111W
    Working Frequency100 KHz ± 10%
    Dimension405*440*130mm (L*W*H)
    Working ModeAblation and resection: level 1-10
    Coagulation: level 1-10
    Weight7.0kg


    Product Advanatages

    • Safety: multi-polar design, change the traditional way that current flow through human body
    • Low Temperature: 40 to 70 centigrade during operation, decrease the thermal damage to around normal tissue
    • Precise cutting: the thin plasma layer make precise cutting becoming true, and it will not hurt the around normal tissue
    • Speedy cutting: cutting and coagulation at the same time, no need to change the probe frequently, saving operation time
    • Shorten recovery period: less hurt to human body, recovery faster


    System Set Up

    1). One tabletop generator device
    2). One reusable and non-sterile power supply cable.
    3). One reusable and non-sterile footswitch.
    4). One reusable and non-sterile treatment handle which is for foot control.
    5). Treatment probes.

    DescriptionRemark
    Manufacturer LogoMECHEN Brand.
    PadsInsulation and support on the surface.
    Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
    Receptacle of Treatment HandleConnects with the treatment accessories.
    Power SwitchSystem start power button. “O” means power off; “I” means power on.
    ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
    Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
    Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
    ABLATION Power Setting DisplayShows the preset ABLATION output value in two digits.
    “01” with Min. power output, and “10” with the highest output.
    Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.


    ENT System Features

    1. Push-button operation, easy to use;
    2. Real-time monitoring of the tissue impedance value during the surgery to tell the degree of surgery;
    3. peeling cutting probe(electrode), cutting is more convenient and rapid;
    4. more surgical electrodes to choose to meet more parts of tissue ablation, cutting, coagulation and hemostasis;
    5. ablation cutting mode 1, ablation cutting mode 2, to meet the ablation cutting needs of different organizations.

    Scope of Adaption

    The plasma surgery system is used in conjunction with the disposable plasma probes, suitable for ablation, cutting, coagulation and hemostasis of human tissue. It needs to be used in a saline environment.


    Storage Condition


    This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:

    1. Temperature: -40℃~+55℃;

    2. Relative humidity: ≤90%;

    3. Atmospheric pressure: 50kPa~106kPa


    Product Tags:

    rf ablation system

      

    rf ablation devices

      
    Quality MIS Snoring Treatment ENT Plasma Surgery System Low Temperature Coblator for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Chengdu Mechan Electronic Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)