Sign In | Join Free | My burrillandco.com
Home > Plasma Surgery System >

Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight

Chengdu Mechan Electronic Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight from wholesalers
     
    Buy cheap Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight from wholesalers
    • Buy cheap Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight from wholesalers
    • Buy cheap Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight from wholesalers
    • Buy cheap Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight from wholesalers

    Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight

    Ask Lasest Price
    Brand Name : MECHAN
    Model Number : PLA-700
    Certification : CE, ISO13485
    Price : Negotiation
    Payment Terms : T/T, L/C
    Supply Ability : 100000 sets per year
    • Product Details
    • Company Profile

    Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight

    Snoring Treatment System ENT Plasma Surgery System Coblation Coblator


    Product Introduction


    MECHAN ENT Plasma Surgery System PLA-700 are designed to operate in ENT field, it includes both ablation and coagulation modes, which result in different tissue effects. It is widely applying to Turbinate, Soft Palate, Uvula, CAUP, UPPP, Tonsillectomy, Adenoidectomy, Laryngeal tumor, Papilloma, Vocal Polyps etc.


    Product Diagram



    Working Principle


    A 50 μm plasma area is formed around the electrode through a conductive medium (mainly H2O, NaCl and air). Unlike traditional electrosurgical methods, which separate and solidify tissues by heating the tissue, Metron plasma knives use the kinetic energy generated by the rapid movement of plasma in an electric field at 100 kHz to decompose the tissue, thereby achieving the purpose of cutting and clotting.

    Technical Parameter


    Input Volts

    198-240V 50Hz

    100-120V 60Hz

    Export device could convert automatically per customer requirements

    Output Power

    Ablation or resection: ≤351W

    Coagulation or hemostasis: ≤111W

    Working Frequency100 KHz ± 10%
    Dimension405*440*130mm (L*W*H)
    Working Mode

    Ablation and resection: level 1-10

    Coagulation: level 1-10

    Weight7.0kg

    Product Advanatages


    • Safety: multi-polar design, change the traditional way that current flow through human body
    • Low Temperature: 40 to 70 centigrade during operation, decrease the thermal damage to around normal tissue
    • Precise cutting: the thin plasma layer make precise cutting becoming true, and it will not hurt the around normal tissue
    • Speedy cutting: cutting and coagulation at the same time, no need to change the probe frequently, saving operation time
    • Shorten recovery period: less hurt to human body, recovery faster

    System Set Up


    1). One tabletop generator device

    2). One reusable and non-sterile power supply cable.

    3). One reusable and non-sterile footswitch.

    4). One reusable and non-sterile treatment handle which is for foot control.

    5). Treatment probes.


    DescriptionRemark
    Manufacturer LogoMECHEN Brand.
    PadsInsulation and support on the surface.
    Receptacle of FootswitchConnects with Footswitch which determines ablation or coagulation mode.
    Receptacle of Treatment HandleConnects with the treatment accessories.
    Power SwitchSystem start power button. “O” means power off; “I” means power on.
    ABLATION mode SelectorSelect ABLATION mode 1 or 2 Output waveform.
    Indicator of Treatment Probe ConnectionLED turns on green when the probe cable is connected and turns on red when it is not connected.
    Indicator of Footswitch ConnectionLED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
    ABLATION Power Setting Display

    Shows the preset ABLATION output value in two digits.

    “01” with Min. power output, and “10” with the highest output.

    Ablation Output Power Up/Down ButtonThe number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

    Storage Condition


    This device should be stored in a well-ventilated room without corrosive gas. The height above ground and the distance from wall should be above 30cm. Stack limit is 6 cases. Before being stored for a long time, it should be cleaned thoroughly for proper packing and storage. And it should also be taken out for power up every year, in order to avoid it from moisture, mildew or even damage. The suitable weather and environment condition is as below:

    1. Temperature: -40℃~+55℃;

    2. Relative humidity: ≤90%;

    3. Atmospheric pressure: 50kPa~106kPa


    Product Tags:

    rf ablation system

      

    rf ablation devices

      
    Quality Snoring Treatment ENT Plasma Surgery System Minimally Invasive Lighweight for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Chengdu Mechan Electronic Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)